How Challenging Is Your Drag Reducing Agent?
After testing many pumps, Clariant turned to CheckPoint Pumps and Systems to devise a reliable dosing method for its highly effective but difficult-to-handle drag reducing agent. The chemical is very sensitive to ambient temperature and has a viscosity of 500 to 2000 centipoise (5 to 20 poise). It also solidified into lumps inside the IBC tank, making it almost impossible to enter the pump suction, let alone pass through the filter.
CheckPoint added a double-diaphragm pump to precharge the suction end of a model 8400 pneumatic process pump. This arrangement proved capable of maintaining a constant flow of 53 USG/H (200 L/H) at a discharge pressure of 5,400 PSIG (372 BARG).
The production package contained two pumps in a 316 SS stainless steel framework and included an electronic flow meter at the discharge point with instantaneous and totalized readouts. The system has operated 24 hours a day, 7 days a week since April 2004 under the harsh offshore conditions of the North Sea.
Drag Reducing Agent (DRA)
- Many Competing Pumps Failed After Only a Few Hours of Use
- Variable Viscosity
- Extreme Temperature Conditions, Clariant/Petrofac/BP, North Sea